- 美國(guó)Masterflex
- OMEGA熱電偶
- OMEGA熱電偶線
- OMEGA熱電偶補(bǔ)償導(dǎo)線
- OMEGA插頭插座面板
- OMEGA熱電阻
- OMEGA熱敏電阻
- OMEGA變送器
- OMEGA高溫膠
- OMEGA紅外溫度測(cè)量?jī)x器
- OMEGA溫濕度標(biāo)簽
- OMEGA溫濕度計(jì)
- OMEGA溫濕度傳感器
- OMEGA泵和混合器
- OMEGA校準(zhǔn)器
- OMEGA壓力計(jì)
- OMEGA壓力表
- OMEGA壓力開(kāi)關(guān)
- OMEGA壓力傳感器
- OMEGA稱(chēng)重傳感器
- OMEGA應(yīng)變片
- OMEGA液位開(kāi)關(guān)
- OMEGA液位傳感器
- OMEGA閥門(mén)
- OMEGA流量計(jì)
- OMEGA扭矩傳感器
- OMEGA位移傳感器
- OMEGA加速度計(jì)
- OMEGA風(fēng)洞
- OEMGA風(fēng)速計(jì)
- OMEGA萬(wàn)用表
- OMEGA pH和傳導(dǎo)
- OMEGA加熱器
- OMEGA信號(hào)調(diào)節(jié)器
- OMEGA數(shù)據(jù)記錄儀
- OMEGA I/P轉(zhuǎn)換器
- OMEGA數(shù)據(jù)采集
- OMEGA自動(dòng)化
- OMEGA數(shù)顯表
- OMEGA壓力應(yīng)力重力傳感器
- 圣戈班軟管
- 美國(guó)Antylia
- 美國(guó)Cole-Parmer
- 德國(guó)HelixMark
- Cole-Parmer流量計(jì)
- 美國(guó)Masterflex泵管
- 道康寧/Dow Corning硅膠管
- Kinesis
- 美國(guó)pyrex
- 美國(guó)zefon
- Nasco Whirl-Pak無(wú)菌采樣袋
- 英國(guó)STUART
- 美國(guó)JACO
- Ismatec泵|軟管
- 日本Horiba
- 英國(guó)Burkard布卡德
英國(guó)Burkard MEI0049氣旋表層取樣器可以應(yīng)用于:
1)醫(yī)藥學(xué)方面,用于收集房間內(nèi)的過(guò)敏源塵、花粉;
2)農(nóng)業(yè),從植物體上收集病原體孢子或者從動(dòng)物身上或動(dòng)物飼舍中收集粉塵;
3)工業(yè)上可以用于進(jìn)行例行的表層樣品收集,以保證所需的衛(wèi)生條件及檢測(cè)有害污染物;
4)在法醫(yī)學(xué)或環(huán)境污染方面,必要的話,它可以為特定的顯微污染物采集基質(zhì)。
高度 230 mm (9 inches)
寬度 110 x 45 mm (4.3 x 1.8 inches)
凈重 520 g (1.2 lb)
收集容器: 25 x 50 mm (1 x 2 inches)
旋風(fēng)口: 9 x 3 or 9 x l mm (0.35 x 0.1 or 0.35 x 0.04 inches)
Product Description
The high efficiency of small cyclones in retaining particles from an air stream has been adapted to provide a convenient means of collecting dry surface deposits from a wide variety of materials. For applications in medicine the house dust allergen, pollens: or in agriculture, spores of plant pathogens, dusts from animals or in animal houses; in industry for routine sampling of surfaces to ensure hygiene and help detect deleterious contaminants for forensic and environmental pollution where it is necessary to sample substrates for particular microscopic contaminants.
Effectiveness of the orifice in sampling surface deposits depends largely on a very fast intake velocity to provide strong ‘rip-off’ . For this reason the standard orifice has been decreased in cross section to l x 9 mm. Effective operation of this cyclone requires a powerful pump capable of maintaining at least 18 cm (7 inches) mercury pressure difference while displacing 16.5 l/min of air through the cyclone via a critical orifice installed in the handle.
For dry powders where almost all the deposit is collected in the catchpot, samples from equal areas should be quantitatively comparable (even gravimetrically from dense deposits). The retention efficiency of the cyclone means that very little escapes but it is possible to install an ultimate filter stage. The cyclone has been designed with a stub-intake in order to fit alternative sampling orifices as required. Burkard will be pleased to advise or construct other orifices that may be found best for particular purposes. Samples are collected in small tubes which are readily detached capped and replaced by releasing a spring plunger in the base of the handle. This action also release the cyclone unit which is easily taken to pieces for cleaning or replacement.
Additional information
Overall height |
230 mm |
---|---|
Overall width |
110 x 45 mm |
Nett weight |
520 g |
Collecting vessel |
25 x 50 mm |
Cyclone orifice |
9 x 3 or 9 x l mm |
Vacuum hose |
6 mm bore |